Fluke T5 Voltage, Continuity and Current Testers.
Fluke 62 MAX+. Small in size. Big on toughness.
This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.
Fluke T5-600 Voltage, Continuity and Current Tester
| Specifications | ||
| Jaw opening | 12.9 mm (0.5 in) | |
| Max wire size | 1/0 THHN cable | |
| Current range AC rms | 0 to 100.0 A | |
| Accuracy AC current (50/60 Hz) | 3% ± 3 counts | |
| AC Response | Averaging | |
| Voltage range AC | 0 to 600 V | |
| Accuracy AC voltage | 1.5% ± 2 counts | |
| Voltage range DC | 0 to 600 V | |
| Accuracy DC voltage | 1% ± 1 count | |
| Resistance range | 0 to 1000 Ω | |
| Continuity beeper threshold | On at < 25 Ω, off at > 400 Ω | |
| Volts indicator LED threshold | Guaranteed on by 30 V AC | |
| Environmental Specifications | ||
| Operating temperature | -10°C to 50°C | |
| Storage temperature | -30°C to 60°C | |
| Humidity (without condensation) | 0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C); 0% to 45% (40°C to 50°C) |
|
| Dust/water resistance | Yes | |
| Operating altitude | 2000 meters max | |
| Temperature coefficient | 0.1 x (specified accuracy)/°C (< 18°C or > 28°C) | |
| Safety Specifications | ||
| Measurement Category | IEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac | |
| Agency approvals | CSA, TUV | |
| Maximum voltage | 600 V between any terminal and earth ground | |
| Mechanical and General Specifications | ||
| Size | 30.5 x 51 x 203 mm | |
| Weight | 300 g | |
| Warranty | Two-years | |
| Battery life | 200 hour zinc chloride, 400 hour alkaline | |
| Battery type | 2 x AA | |
| Low battery indicator | Yes | |
| Current sensor opening | 12.9 mm | |
| Calibration cycle | 1 year | |
| Test leads | Type | Heavy duty, flexible leads rated for 1000 V use. Field replaceable leads terminate in male shrouded banana plugs |
| Probes | One red, one black. Detachable Slim-Reach™ probe tips |
|
| Styles | TP1 Slim Reach™ test brobes | |
| Safety Specifications | ||
| Safety | CAT IV 600 V, CAT III, 1000 V | |
| Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 | |
Fluke 62 MAX+ Infrared Thermometer
| Specifications | ||
| Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
| Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 |
|
| Response time (95%) | < 300 ms (95% of reading) | |
| Spectral response | 8 to 14 microns | |
| Emissivity | 0.10 to 1.00 | |
| Optical resolution | 12:1 (calculated at 90% energy) | |
| Display resolution | 0.1°C (0.2°F) | |
| Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
| Power | AA battery | |
| Battery life | 8 hours with laser and backlight on | |
| Physical Specifications | ||
| Weight | 255 g (8.99 oz) | |
| Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
| Operating temperature | 0°C to 50°C (32°F to 122°F) | |
| Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
| Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
| Operating altitude | 2000 meters above mean sea level | |
| Storage altitude | 12,000 meters above mean sea level | |
| IP rating | IP 54 per IEC 60529 | |
| Drop test | 3 meters | |
| Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
| EMC | EN 61326-1:2006 EN 61326-2:2006 | |
| Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
| Laser safety | FDA and EN 60825-1 Class II | |
Includes:
电 话:173-0381-6163
传 真:+86-0371-69082289
手 机:173-0381-6163
邮 箱:1654991910@qq.com
地 址:郑州市中原区陇海西路300号3-2-2602室